User Manual
Technical Information / Datasheet
POWERLINK Bus module SK CU4-POL
1.1 LED - displays, derating, Error 10.9 4913 Rck TI 275271018 GB
version reason for change(s) issue name document speech
Pos: 4 /T echnis che Inf orma tion en/SK xU x - Bus - Er weit erung en/ P owerl ink /SK C U 4-POL / 2752 71018 / Basi sinf orma tione n [SK CU 4-POL] @ 4 \mod_1378286286736_388.docx @ 92892 @ 555 @ 1
SK CU4-POL
Part number: 275 271 018
POWERLINK - Internal bus interface
NOTICE
Validity of the documents
This document is only valid in combination with the operating instructions for the relevant frequency inverter.
All of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.
Scope of supply
1 x Module SK CU4-POL
1 x System bus cable set grey / black
1 x 24 VDC cable set brown / blue
2 x Connecting screws M4 x 20, cross-head
Field of use
Internal interface for connecting a decentralised frequency inverter (SK 180E … SK 2xxE) to a
POWERLINK field bus. It is connected to the inverter via the system bus, and can communicate
directly with up to 4 frequency inverters. 2 digital inputs are available.
Technical data
Module
Temperature range -25°C … xx °C * Vibration resistance 3M7
Temperature class Class 3k3 Firmware version V1.2 R0
Protection class IP20 Hardware version AA
Supply voltage 24 V ± 20 %, ≈ 100 mA
Reverse polarity protected
* The upper temperature limit depends on the frequency inverter and the operating mode à see "Derating"
Digital input - working area Low: 0 V … 5 V, High: 15 V … 30 V
Digital input - specific data R
i
= 10 kΩ, input capacity: 10nF, reaction time 1 ms, inputs
according to EN 61131-2 type 1