NUR-10W HW Implementation Guide v1.4
Manufacturer Part Number: ARx5_antenna
Gain: 6dBi
Option 2:
Manufacturer: Nordic ID
Antenna Description: Cross Dipole antenna with reflector
Frequency range: 902 928 MHz
Manufacturer Product Name: Medea_ACD_antenna
Gain: 5dBi
Option 3:
Manufacturer: TBD
Antenna Description: TBD
Frequency range: TBD
Manufacturer Product Name: TBD
Gain: TBD
11.3 INDUSTRY CANADA
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause
undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
To leverage the Nordic IDs IC grant, the device with the integrated NUR-10W module shall be met the
following conditions:
1. The antennas being the approved types with the maximum gain of 5dBi and of 6dBi shall be installed so
that the device’s user or nearby people or passing people cannot compromise the minimum separation
distance of 30cm and of 34cm, respectively, in any situation. If the antenna being one of the approved