Then choose, if desired, the action id number. Modi er (shift, alt or function) and virtual key to be mapped
to. The misc –tab has controls to the input mode selection (123, abc or ABC), Scan mode –selection ( and
the control of the lights of the input mode keys.
The con gured keymappings can be saved as a pro le or to system default.
6.5.16 NID Power Button
Fig.66 Mapping-tab
Power button con guration program is for con guring the power-key behavior. The default function of the
power-key is to open the shutdown menu but it can be mapped to execute any program. After the holding
the power-key for a “hold time” (in milliseconds) the PL3000 goes to suspend mode.
The power-key can also be mapped to function as any virtual key.
The con gured power-key behavior can be saved as a pro le or to system default.
6.5.17 NID Scanner
The scanner con guration –program is for con guring the scanner functions. The program has 4 tab pages;
Codes, Misc, Scan and Pro les.
The actions to the keys are set from Mapping-tab below the Actions.
There are 50 action identi ers and each of them can be set to launch an
external program. First set and action id number (1-50) and then browse
the selected action. The parameters can be written after the selected
executable.