Owner's Manual

26
Lower the treadmill (see HOW TO LOWER THE
TREADMILL FOR USE on page 24). Remove the
three #8 x 3/4" Screws (1). Carefully pivot the
M
otor Hood (71) off.
Locate the Reed Switch (52) and the Magnet (50)
on the left side of the Pulley (49). Turn the Pulley
until the Magnet is aligned with the Reed Switch.
Make sure that the gap between the Magnet
and the Reed Switch is about 1/8 in. (3 mm). If
necessary, loosen #8 x 3/4" Tek Screw (13), move
the Reed Switch slightly, and then retighten the
Screw. Reattach the Motor Hood (not shown) with
the five #8 x 3/4" Screws (not shown) and run the
treadmill for a few minutes to check for a correct
speed reading.
SYMPTOM: The incline of the treadmill does not
change correctly
a. Hold down the Stop button and the Speed increase
button, insert the key into the console, and then re-
lease the Stop button and the Speed increase but-
ton. Press the Stop button and then press the
Incline increase or decrease button. The treadmill
will automatically rise to the maximum incline level
and then return to the minimum level. This will recal-
ibrate the incline system. If the incline does not cali-
brate, press the Stop button again, and then press
the Incline increase or decrease button again.
When the incline is calibrated, remove the key from
the console.
SYMPTOM: The walking belt slows when walked on
a. Use only a single-outlet surge suppressor that
m
eets all of the specifications described on page 14.
b
. If the walking belt is overtightened, treadmill perfor-
mance may decrease and the walking belt may be-
come damaged. Remove the key and UNPLUG
THE POWER CORD. Using the hex key, turn both
idler roller screws counterclockwise, 1/4 of a turn.
When the walking belt is properly tightened, you
should be able to lift each edge of the walking belt
2 to 3 in. (5 to 7 cm) off the walking platform. Be
careful to keep the walking belt centered. Then,
plug in the power cord, insert the key, and run the
treadmill for a few minutes. Repeat until the walk-
ing belt is properly tightened.
c. If the walking belt still slows when walked on, see
the front cover of this manual.
Top
View
50
52
13
1/8 in.
49
Idler Roller Screws
2–3 in.
b
71
1