Owner manual

7-12 Specifications
Table 7-10 Fluid Heater Specifications
Characteristic Specification
Needle Heater (DP, DV):
Control Fluidmove software programmable, closed-loop PID controller
Temperature Range
Ambient to 120 °C (248 °F)
Accuracy
±5 °C (33.8 °F)
Temperature Sensor Resistance Temperature Detector (RTD)
Heating Element
Power Output
24 VDC, 1 A, 6 W peak
Fuse Rating 3 Amperes
Thermal Control Assembly (DJ-9000):
Body 6061-T6 Aluminum, Nickel Plated
Heating Element
Power Output
24 VDC, 14.7 watts, 40 ohms
Temperature Sensor RTD, 100ohm, platinum
Temperature Range
Ambient to 80 °C (176 °F)
Note: Refer to 3.9 Fluid Heaters for additional information.
Table 7-11 Heater Tooling Specifications
Characteristic Specification
Contact and Impingement Tooling:
Control Fluidmove software programmable, closed-loop PID controller
Types Available Contact or Impingement
Temperature Sensor Thermocouple (standard)
Resistance Temperature Detector (RTD) (option)
Tooling Surface
Temperature
120 °C (302 °F) maximum
Accuracy
±5 degrees at 80 °C (176 °F)
Over-temperature Safety Thermally resettable thermostat.
Heat Stations Up to three independently configured substrate heating stations
(pre-heat, dispense-heat, and post-heat) with closed-loop
programmable set point control
Impingement Tooling
Heating Zone/Board Size
90 x 250 mm (3.5 x 9.8 in.) / 96.5 mm (3.8 in.)
50 x 250 mm (2.0 x 9.8 in.) / 66.5 mm (2.6 in.)
Process Development Hotplate:
Size 317.5 x 279.4 mm (12.5 x 11 in.)
Temperature Range
Ambient to 120 °C (248 °F) with ±5 °C (41 °F) uniformity
Vacuum 95 kPa (-16 in Hg) maximum
Heating Time
Up to 90 °C (194 °F) in 15 minutes
Cool-down Time
From 100°C (212 °F) to 60 °C (140 °F) in 30 minutes
or
From 100°C to 40 °C (122 °F) in 50 minutes