5-6 Start-up/Shutdown
Shutdown
You can shut your Century Series system down due to an Emergency, a Production
Shutdown at the end of a shift and for a Service Shutdown.
Emergency Shutdown
1.
Press E-Stop. (This only turns off power to the mechanics. A Needle Heater run by
an HT-1000 or a computer and monitor attached to the Century Series system will
remain on.)
2.
Press the Main Power Switch on the rear of the Century Series system
OFF
( ) to
completely power
OFF
the system.
You must use both the E-Stop
and
the Main Power Switch on the
back of the machine to turn the Century Series system completely
OFF
for servicing after any emergency E-Stop shutdown
.
Operator Shutdown/End of Shift in FMW
The following recommended procedures for a production shutdown can vary for your
particular application.
To shut down at the end of a shift:
1.
End your dispensing program in FMW.
Click
from the Run Window screen.
Click from the Production Window screen.
Click from the Main Window screen.
2.
Remove workpieces from the dispensing area.
3.
Remove the syringe from the dispense head.
4.
Clean or purge your fluid pump.
Refer to your Valve or Fluid Pump Manual for help, if necessary.
5.
Press the Power Switch on the Control Panel
OFF
( ).
6.
Exit Windows and power down the computer.