9-6 Vision Systems
7.
Select if you are satisfied with the camera offset.
If you select , Fluidmove automatically begins the Needle Sensor Setup
procedure. To perform a Needle Sensor Setup procedure without first
performing a Camera Offset, simply select from the
Setup menu.
Read the initial instructions displayed on-screen preceding
this procedure before continuing.
8.
Use the front panel arrow controls to guide the needle into the Needle Sensor slot
entrance at the front of the Needle Sensor. Slowly move into the slot until the green
LED on the Needle Sensor turns ON.
Follow all on-screen prompts.
9.
Use the front panel arrow controls to move the needle slowly around the corner
until the green LED turns ON again.
10.
Enable the Z-Axis controls and slowly raise the needle until the green LED turns
OFF.
11.
Press [F5]
or [Pause].
The dispensing head will move after your response.
To adjust the brightness of the video display:
1.
Twist the f-stop ring on the camera lens.
Reach up from below the light ring to perform this adjustment.
2.
Check the light level.