Manual

10-12 Height Sensor
3.
Using the 1/16 inch hex key, turn the FU adjust screw to adjust the GU stroke
length.
To reduce the stroke length, turn the GU adjust screw to the left.
To increase the stroke length, turn the GU adjust screw to the right.
4.
Go to the Terminal Mode Window by selecting from the Fluidmove
menu in FMDOS, or by clicking on in the FMW Main Window, then
clicking on and clicking on .
5.
Issue GU and GD commands to test for interference while checking to see if the
probe contacts the needle or any other device.
6.
When you are satisfied with the settings, tighten the GU adjust screw by turning
it two full revolutions to the right.
Refer to Figure 10-4 for locations of the GU adjust screw and the GU adjust
locking screw.
7.
Run a Height Sensor Setup procedure (see “Setup” on page 10-4 for
instructions).
Figure 10-4 GU Adjustment Locations
G
U Adjust Screw
GU Adjust Locking
Screw (near stem
of GU adjust
screw)