User guide

5-4 Startup/Shutdown
3. Select Calculate Master Offsets from the cascading menu.
> If Calculate Master Offsets is not available, select Machine Offsets Parameters and
activate
Calculate Master Offsets in the Machine Offsets Parameters dialog box.
4. Under
Machine Offsets Mode, select Calculate Master Offsets.
?
NOTE If you are changing from Valve Offsets to Calculate Master Offsets, it is recommended
that you exit FmNT and restart before performing the
Calculate Master Offsets routine.
5. Enter Machine Setup Parameters; click
OK.
6. Follow the on-screen prompts to complete the setup.
> Consult the Fluidmove for Windows NT User Guide or FmNT Online Help for assistance.
?
NOTE Calculate Master Offsets and Find Needle XYZ must be used together.
Valve Offsets
Valve Offsets takes you through a series of on-screen prompted functions for defining the XYZ locations
of the Purge and Weigh Stations, calculating the needle-to-height sensor Z offset, the needle-to-camera
XY offset, and the camera-to-height sensor XY offset. This routine is typically performed after initial
start-up if significant changes to the system are made or if the dispensing system or software is upgraded
or reinitialized. See the Fluidmove for Windows NT User Guide or Online Help for more guidance.
To perform Valve Offsets:
1. In the FmNT Main Window, click on
Configuration.
2. Choose
Machine Offsets.
3. Select
Valve Offsets from the cascading menu.
> If Valve Offsets is not available, select Machine Offsets Parameters and activate Valve
Offsets
in the Machine Offsets Parameters dialog box. Click on OK.
4. Return to
Configuration.
5. Choose
Machine Offsets.
6. Select
Valve Offsets from the cascading menu.
7. Click on
Run to begin the first machine offsets procedure. Follow the on-screen prompts to
complete the setup routine for your specific application.
8. If your system is configured for dual-action fluid dispensing, repeat the above procedures for
Valve 2.
?
NOTE If you are changing from Calculate Master Offsets to Valve Offsets, it is recommended
that you exit FmNT and restart before performing the
Valve Offsets routine. See the
Fluidmove for Windows NT User Guide or Online Help for more guidance.