6 Installation
To install the DispenseJet:
1. Install the appropriate Z-head mounting plate (valve bracket) and bracket mount for the
dispensing system. Refer to Ordering Parts” in the Additional Information section for part
numbers.
NOTE These instructions assume that the co-axial air solenoid valve has not been installed
to the DispenseJet.
2. Mount the jet to the Z-head mounting plate and tighten with a 3-mm hex wrench.
3. Make the electrical connections according to the machine configuration shown in Figure 3-1 and
Figure 3-2.
4. Connect the pneumatic air lines as shown in Figure 3-1 and Figure 3-2. You should hear a click
when the hose is inserted properly.
5. For syringe installation and replacement, see “Changing the Syringe” in the Operation section.
Item Description Item Description
1 Fluid Air Pressure (Clear) 6 Mounting Screws (two)
2 Syringe and Clear Fluid Pressure Line 7 Electrical Cable
3 Syringe Bracket 8 Heater Power Connector
4 Z-mounting Plate 9 Temperature Controller Connector
5 DispenseJet 10 Solenoid Valve Electrical Connector
Figure 3-1 Installing the DispenseJet to the C-730 Dispensing System
5
4
6
7
1
8
10
2
3
9