16 Operation
Setup and Valve Offset Routines
The Fluidmove software uses prompts that can be followed to properly dispense, prime, purge, and refill
fluid. Parameters set in the Fluidmove dispensing software determine how long the valve remains open to
dispense each line or dot. Follow the instructions in the applicable dispensing system Operations Manual
and the Fluidmove User Guide.
NOTE The DJ-2200 DispenseJet setup process in Fluidmove must be performed prior to
programming the dispensing system and using the DJ-2200 DispenseJet. The setup is
identical for flux dot and flux line applications.
Changing the Syringe
To change the Syringe (Figure 4-4):
This procedure assumes you using the same fluid. If you are changing fluids, see Changing Fluidslater in
this section.
1. If required, allow fluid to reach room temperature (refer to the MSDS for your fluid to determine
requirements).
2. Inspect the fluid in syringe for air bubbles.
NOTE Do not use any samples with visible air bubbles, as these will cause fluid voids and
dispensing irregularities.
3. Remove the orange cap from the flat end of the syringe.
4. Check that the syringe has either an orange no-draft follower (preferred) or a yellow follower.
5. Remove the syringe tip cap.
6. Slide the receiver head onto the flat end of the syringe and tighten it.
7. Place the tip of the syringe securely into the elbow connector.
NOTE It is important to position the receiver head so that the long sides are parallel to the
X-axis rods. If it is slanted or perpendicular to the X-axis, the receiver head will hit
the Z-head during dispensing.
8. Tighten the thumbscrew on the syringe bracket.
CAUTION! Do not over-tighten the syringe thumbscrew. Over-tightening may cause the
syringe to deform, forcing large amounts of fluid into the fluid chambers.
9. Connect the clear line from the receiver head to the clear (leftmost) line on the dispensing head.