Manual

Beginning Programming 6-31
Exercise 6-3: Editing Line Parameters
1. Perform the Programming Setup routine as described in “Programming Setup” in the
Programming Basics and Setup section.
2. Load Side 1 of the Tutorial Board.
3. In the Main Window, click on
Teach a Program.
!The Programming Window opens.
4. In the Programming Window, select
File>New or click on the Program Wizard icon.
5. Select
One fiducial and Teach Workpiece Origin.
!You will now be prompted to teach the workpiece origin and fiducials.
" NOTE Refer to the Programming Basics and Setup section for instructions on program
setup and defining workpiece alignment, origin, and fiducials.
6. Click the
Dispensing Elements button on the Program Commands toolbar.
!A Teach Window opens.
7. Click on Weight Control Lines.
8. In the
Total Weight text box type: 20
!Entering
20 means that 20 mg of fluid will be dispensed along the length of the line you
will now define.
9. Move the camera crosshairs to the beginning of the top Basic Line on Side 1 of the
Tutorial Board.
10. Click on
Teach.
11. Move the camera crosshairs to the end of the line.
12. Click on
Teach.
13. Click on
Done.
!A message box opens, indicating the calculated line speed for the newly created weight
control line.
14. Click on
OK.
!The Workpiece Pattern program should appear as follows:
1 WEIGHT CONTROL: 20.000, 1,...
2 END