Manual

A-4 Appendix A - Programming Menu Detail
The disabled command(s) appears in red text within the dispensing program. When the
dispensing program runs, the disabled command(s) will not execute.
To re-enable the command(s), highlight the line(s) again, click on
Program>Instruction >
Enable Instruction.
16. Height Sense
- Opens a drop-down menu containing Height Sensor options.
Auto Height Sense On
- Inserts an Auto Height Sense On command into your dispensing
program, which enables all height sensing. This is the default setting.
Auto Height Sense Off
- Inserts an Auto Height Sense Off command into your dispensing
program, which disables the height sensing operation and uses the last height recorded. Height
sensing will remain disabled until a Height Sense On command occurs or the program is
restarted.
If a Find Substrate Height command occurs after this command, it will execute.
Set Height Sense Mode
- This command is automatically inserted at the beginning of the Main
Program, before the DO: Workpiece AT (xx,yy) command. If this command does not occur in
the Main Program, FmNT will issue an error and abort the run.
17. Pattern
– Opens a drop-down menu containing pattern-related commands.
Create
- Opens a dialog box for naming a new pattern.
Place
- Once you create a pattern, it does not automatically become part of your program. You
must insert the pattern by selecting Place Pattern.
Place Multipass Pattern
- Opens a Teach Window for placing a previously created Multipass
pattern at various locations on the workpiece.
Step and Repeat
- Opens a Teach Window in which you can specify the Step and Repeat
parameters for placing the selected program at multiple locations on a workpiece.
Loop Block
- Used to insert a Multipass pattern into a Main Dispensing Program.
Pass Block
- Used to setup the programming of a Multipass pattern.
18. Process Commands
- Accesses a drop-down menu containing the various Process Commands.
Find Substrate Height
- Determines workpiece height.
Purge
- Inserts a purge command into a program.
Measure Flow Rate
- Inserts a Measure Flow Rate command into a program.
Create Procedure
- Opens a dialog box for creating a new procedure.
Call Procedure
- Opens dialog box for inserting a procedure into a program.
Send Dispenser
- Opens dialog box for inserting ACL or PMAC commands directly into a
dispensing program.