Instruction Manual
Troubleshooting 6-9
Figure 6-10 Hidden System Configuration
Table 6-5 Hidden System Configuration Options
Setting/Parameter Description
Applicable
Configurations
Stepper Conveyor
Indicator Selected (green): Stepper Conveyor Motor
Indicator not selected: DC Conveyor Motor
All
Accel
Elevator/Shuttle
Acceleration value for elevator, shuttle All
Decel
Elevator/Shuttle
Deceleration value for elevator, shuttle All
Top Shelf Load
Shuttle/Elevator
Coordinates of top shelf Dual Shelf Only
Bottom Shelf Load
Shuttle/Elevator
Coordinates of bottom shelf All
Stop at Mid Time
Pause time of gripper when pulling a part from the
magazine
Loader, Same-Side
Loader Only
Watchdog Timeout Timeout for conveyor, load, and unload processes All
Overtemp Limit Oven temperature limit Oven special only
SS Loader Select for Same-Side Feed Loader Configuration Same-side loader only
Loader Select for Loader Configuration Loader only
Unloader Select for Unloader Configuration Unloader only
PID PID parameters for oven controller Oven special only
Teach Global Values
Enters typical values into acceleration, deceleration,
and other global variable field
All
Zero Globals and
Recipes
Changes values of all global and recipe parameters
to zero
All
Shelves: Single/Dual Select between single and dual shelf configurations
All except same-side
loader and oven special
Motor Type Select elevator motor type All
Thin Strip Guides Enables thin strip guides Same-side loader only