Instruction Manual
Backup and Restoration 7-5
8. In the [MC] menu we can transfer from the memory cassette to the PLC (>MC -> PLC) or
from the PLC to the memory cassette (>PLC->MC). See additional notes below for Autboot
PRG/RUN details shown after selecting MC->PLC. For the MH-900, Autboot RUN is
recommended. Arrow up/down, then press OK to select your desired function.
9. Press the down button to select >OK, then press OK.
Warning! This will overwrite the data in the destination device.
10. The transfer will begin and display current progress.
11. When the loading is finished, Complete will be displayed.
NOTES (1) The Compare menu option can be used to verify the content of the memory
cassette and the PLC before a transfer is initiated.
(2) AUTBOOT PRG: The PLC will enter program mode after loading the program from
the memory cassette immediately after power (PLC dip switch settings are
configured for Auto Transfer: ON).
(3) AUTBOOT RUN: The PLC will enter run mode after loading program from the
memory cassette immediately after power (PLC dip switch settings are configured
for Auto Transfer: ON).
(4) The CP1W-DAM01 is not compatible with CP1E hardware.
(5) The CP1W-DAM01 is only mountable in option Port 1.
[MC] PRG
>MC->PLC
PLC->MC
Compare
*
MC->PLC
Cancel
>OK
(All area)
MC->PLC
Load
99%
MC->PLC
Complete