Installation and Setup 3-5
3.7 Connecting to the Facility Air Supply
To connect the system to the facility air supply:
CAUTION! Make sure that facility air pressure meets the requirements specified in
Section 2 - Safety. Higher pressures may damage the equipment.
1. Locate the facility quick-disconnect air hose.
2. Make sure the dispensing system Main Air Regulator(s) is closed. Verify facility air pressure
is at 0 psi.
3. Connect the facility air hose(s) to the quick-disconnect(s) on the Main Air Regulator(s).
4. If not already connected, also connect the air hose(s) to the facility air supply.
Use pliers to tighten the connections.
5. Slowly open the facility air valve and listen for leaks.
If there is an air leak, identify the source, shut off facility air, and fix the leak before
proceeding.
6. Slowly open the Main Air Regulator(s) and listen for leaks.
If there is an air leak, identify the source, shut off facility air, and fix the leak before
proceeding.
Item Description
1 Main Air Gauge
2 Main Air Regulator
Figure 3-4 Main Air Regulator and Gauge