Instruction Manual
3-22 Installation and Setup
3.9.2 Motion System Setup
The Motion System Setup lets you set the shuttle and elevator speed during run mode, the elevator and
shuttle travel limit, and elevator and shuttle travel distance.
Figure 3-35 Motion System Setup
1. Enter the desired values. See Table 3-2.
Table 3-2 Motion System Setup Options
Name Description
Run
Mode:
Shuttle Speed Shuttle speed for production run mode.
Elevator
Speed
Elevator speed for production run mode.
Sweep Shuttle Speed Shuttle speed for sweep move used to push any protruding
parts back into magazine (loader only).
Elevator Travel Limit Maximum elevator travel distance.
Shuttle Travel Limit Maximum shuttle travel distance.
Travel
Distance
Elevator Distance elevator travels during a test routine.
Shuttle Distance shuttle travels during a test routine.
Activate Test
Routine
(Figure 3-36
Activates the shuttle and elevator test routine.
Stops the shuttle and elevator test routine.
Single
Move
When selected, limits test routine to a single move. When
not selected, test routine cycles indefinitely.