Instruction Manual

4-24 Operation
4.10.1 Running a Single Board
To run one board:
1. Select Run One Board from the Production Window (Figure 4-23).
After system initialization is complete, the Run One Part Window (Figure 4-30) opens.
Figure 4-30 Run One Part
2. Verify that the correct recipe is selected. By default, the last selected recipe will be used.
The current recipe name will be displayed at the top right of the Run Window.
WARNING! An incorrect recipe may damage the carriers and/or equipment.
3. If the wrong recipe is selected, press to go back to the Production Window and load
the correct recipe. See 4.9 Loading a Recipe.
4. Select the SMEMA and load options. See Table 4-3.
5. Press
to start the run. Press to pause, and to stop the run.
6. Press
to return to the Production Window.
Table 4-3 Run One Part Options
Name Description
Bypass SMEMA
YES - SMEMA signal will be bypassed.
NO - SMEMA signal will activate.
Load Carrier to
Shuttle Only
YES - Part will stop at shuttle module, sequence ends.
NO - Part travel follow single cycle sequence.