SECS Message Detail 4-57
4.2.99 S10F2 - Terminal Request Acknowledge
S10F2 * H->E
<B [1] ACKC10> . * Acknowledge Code
The Host may send the following values for ACKC10:
Table 4-30 S10F2 ACKC10 Values
ACKC10 Description
0x00 Normal. Host accepts the S10F1.
Other Host rejects the S10F1.
4.2.100 S10F3 - Terminal Display, Single
S10F3 [W] * H->E
<L [2]
<B [1] TID> * Terminal ID
<A [160] TEXT> * Message Text
> .
The Host sends to the Equipment. The Equipment interprets TID as follows:
Table 4-31 S10F3 TID Values
TID Description
Any Equipment displays the text on its CRT.
The Host may optionally set the W-Bit to “1” in S10F3. If so, the Equipment replies with S10F4.
4.2.101 S10F4 - Terminal Display Single Acknowledge
S10F4 * H<-E
<B [1] ACKC10> . * Acknowledge Code
This Equipment may send the following values for ACKC10:
Table 4-32 S10F4 ACKC10 Values
ACKC10 Description
0x00 Normal.