Table A-1 All Variables
Appendix A - All Variables A-2
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
GemAlarmFileName EC 0 A None Gem alarm file name
ConfigAlarms EC 1 U1 None
An EC which controls which Alarm Report message this
Equipment will send.
0 = S5F1 default
1 = S5F71
2 = S5F73
ConfigConnect EC 2 U1 None
An EC which controls which SECS message this
Equipment will use for Connect Request.
0 = S1F1
1 = S1F65
2 = S1F13 default
ConfigEvents EC 3 U1 None
An EC which controls some aspects of the Event Reports
sent by this Equipment.
0 = S6F9 or S6F3
1 = S6F11 or S6F13 default
GemConstantFileName EC 4 A None Gem constant filename
DeviceName EC 5 A[80] None
The Host can change this EC to define a meaningful name
for the equipment.
EstablishCommunicationsTimeout EC 6 U2 None
Time in seconds of how long the equipment will delay after
an unsuccessful Connect Request before sending
another. Valid values are 0-32000.
InitCommState EC 8 U1 None
Initial (power-up) Communications State.
0 = Disabled
1 = Enabled
InitControlState EC 9 U1 None
Initial (power-up) control super-state.
1 = Off-Line
2 = On-Line
Heartbeat EC 10 U2 None
The time in seconds that the equipment will delay before
sending S1F1 to test the link. Units are seconds. Valid
values are 0-3200 (a setting of zero will disable the
heartbeat).