Owner's manual

Table A-1 All Variables (Continued)
Appendix A - All Variables A-15
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
DWVDispenses DV 411 U4 4020
Dispense Weight Verification: number of dispenses that
will be performed.
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVTargetRange DV 412 F8 4020
Dispense Weight Verification Target Range: If range limit
checking is enabled, this variable will contain the
maximum allowable range for the dispense weight
verification routine. If limit checking is not enabled, this
variable will contain “-1”.
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVTargetMinLimit DV 413 F8 4020
Minimum allowable deviation from the target weight of the
dispense weight for the Dispense Weight Verification
routine.
Note: If the verification routine fails and the failed weight
is required, the data variable “SCALEMEASUREMENT1”
(if valve 1) or “SCALEMEASUREMENT2” (if valve 2) will
have the last value read from the scale.
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVTargetMaxLimit DV 414 F8 4020
Maximum allowable deviation from the target weight of the
dispense weight for the Dispense Weight Verification
routine.
Note: If the verification routine fails and the failed weight
is required, the data variable “SCALEMEASUREMENT1”
(if valve 1) or “SCALEMEASUREMENT2” (if valve 2) will
have the last value read from the scale.
Valid only after collection event
“DispenseWeightComplete” occurs.