Owner's manual

Table A-1 All Variables (Continued)
Appendix A - All Variables A-63
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
h_PreventFlowRateIfHtrOff DV 11418 I4 3654 Prevent flow rate calibration if heater is off
h_PreventPurgeIfHtrOff DV 11419 I4 3654 Prevent purge if heater is off
h_OnOff DV 11420 I4 3654 Heater ON/OFF
h_AutoManual DV 11421 I4 3654 Heater auto/manual temperature
h_ManualOutputLevel DV 11422 A[30] 3653 Heater manual output level
h_ScaleUnits DV 11423 I4 3654 Temp scale units (Fahrenheit /Celsius)
h_SetPoint DV 11424 A[30] 3653 Heater set point
h_ProportionalBand DV 11425 I4 3654 Heater proportional band
h_Integral DV 11426 I4 3654 Heater integral
h_Derivative DV 11427 I4 3654 Heater derivative
h_OutputFilter DV 11428 I4 3654 Heater output filter
h_HotColdSpread DV 11429 A[30] 3653 Heater hot cold spread
h_InputType DV 11430 I4 3654 Heater input type
h_InputReadingOffsetBias DV 11431 I4 3654 Heater input reading offset bias
h_InputFilter DV 11432 I4 3654 Heater input filter
h_OutputEnable DV 11433 I4 3654 Heater output enable
h_OutputControlType DV 11434 I4 3654 Heater output control type
h_OutputAction DV 11435 I4 3654 Heater output action
h_OutputHeatCycleTime DV 11436 I4 3654 Heater output heat cycle time
h_OutputHeatLimitPC DV 11437 I4 3654 Heater output heat limit percent
h_OutputHeatLimitTime DV 11438 I4 3654 Heater output heat limit time
h_Deadband DV 11439 A[30] 3653 Heater temp dead band
h_Deviation DV 11440 I4 3654 Heater temp deviation
h_ProcAlarmDelay DV 11441 I4 3654 Heater process alarm delay
h_HighProcAlarmOutput DV 11442 I4 3654 Heater high process alarm output