Owner's manual

Table B-1 Collection Events (Continued)
Appendix B - Collection Events B-15
Collection Event Name CEID
Related
Data Variables
Description
PeriodicFlowrateMeasurement2 5011 None
Collection event when a periodical flow rate measurement for Valve 2
has been performed.
PotLifeWarning2 5012 None
Collection event when the pot life of the dispensing material for Valve 2
has reached a warning level.
PotLifeExpire2 5013 None
Collection event when the pot life of the dispensing material for Valve 2
has expired.
ce_HeaterTempsUpdated 5014
611, 801-868,
SV 1101-1168 and SV
1201-1268
Collection event when the heater temperatures are updated.
ce_DoorOpen 5015 None Collection event when the door is opened.
ce_DoorClose 5016 None Collection event when the door is closed.
ce_DWCA_SetupStarted 5040 641, 643, 645, 648
Initial collection event signaling start of DWCA setup (DJ9K Dot Weight
Pressure Setup).
ce_DWCA_MinPressureCompleted 5041 643, 644
Intermediate collection event when dot weight at minimum pressure has
been completed.
ce_DWCA_MaxPressureCompleted 5042 641, 642
Intermediate collection event when dot weight at maximum pressure has
been completed.
ce_DWCA_SetupCompleted 5043
641, 642, 643, 644, 645,
646, 647, 648
Final collection event when final dot weight and pressure has been
computed and DWCA setup has completed successfully.
ce_DWCA_IntermediateValues 5044 649, 650
Intermediate collection event when a fluid pressure / dot weight has
failed calibration and the routine is adjusting pressure. The tool will retry
unless retries exhausted.
ce_DWCA_SetupFailed 5045 None
Collection event if DWCA setup failed or was aborted by user or tool
error. This collection event signals that the DWCA setup routine (DJ9K
Dot Weight Pressure Setup) has completed unsuccessfully.
ce_DWCA_CPJStarted 5046 645, 648, 651, 652 Collection event signaling start of DWCA CPJ (FLOWRATECALIB).