Owner's manual

Table E-1 SECS/GEM Remote Commands (Continued)
Appendix E - SECS/GEM Remote Commands E-3
Remote Command Description
Optional
Parameters
Return Status Code Description
“FLOWRATECALIB”
Start Flow Rate Calibration
See Appendix F
“FLOWRATECALIB” remote
command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“HS XY OFFSETS”
Start Height Sense XY Offsets
setup
See Appendix F “HS XY
OFFSETS” remote command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“LMO_WP_ALIGN”
Run LMO Workpiece alignment
See Appendix F Local Machine
Offsets Workpiece Align
None
0x00 Command received successfully and is executing
0x40 Not in REMOTE mode
0x45 LMO Workpiece is not enabled
0x46 LMO Workpiece fiducials were not taught
0x47 Cannot execute LMO while program is running
0x48 Cannot execute LMO in programming window
“LOAD BOARD 1”
Load board on conveyor 1
See Appendix F “LOAD BOARD”
remote command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“LOAD BOARD 2”
Load board on conveyor 2
See Appendix F “LOAD BOARD”
remote command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running cannot execute command