Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-21
Table F.8-8 Fluid File Parameter ChangeData Variables
Data Variable Name ID
SECS
Type
Related CEID Description
FluidFilenameChanged 455 A[100]
3651
3652
Name of the fluid file being modified. Note that the parameters will
not be persistent unless the fluid file is saved.
FluidTypeChanged 456 I2
3651
3652
Type changed:
0 = Characteristic
1 = Dot/Line Type 1
2 = Dot/Line Type 2
3 = Dot/Line Type 3
4 = Dot/Line Type 4
5 = Dot/Line Type 5
6 = Dot/Line Type 6
7 = Dot/Line Type 7
8 = Dot/Line Type 8
9 = Dot/Line Type 9
10 = Dot/Line Type 10
FluidFileChangedValveNumber 457 I2
3651
3652
Valve Number Fluid File is currently mapped to:
1 = Valve 1
2 = Valve 2
Fluid File Data Variables
The following data variables and their IDs are for reference only and their values should not be directly requested. They are valid only at the time of their
modification and one of the collection events listed above.
Table F.8-9 Fluid File - Data Variables
Data Variable Name ID
SECS
Type
Storage
Type
Fluid File Entry
[Dot Parameters]
fd_OnTime 11000 A[30] FLT On Time
fd_DwellSecs 11001 A[30] FLT Dwell Secs
fd_DispenseGap 11002 A[30] FLT Dispense Gap
fd_Notes 11003 A[100] ASCII Notes
fd_MidmoveCount1 11004 A[30] FLT Midmove Count 1