Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-37
F.17 Flow Rate CalibrationRemote Command
Flow Rate Calibration is a process to measure dispensed fluid weight accuracy and consistency. This is accomplished by taking several sequential dispense
measurements and computing the average fluid weight and flow rate data. The SECS/GEM host can start this process with a remote command sent to the
client machine. The following tables describe the SECS/GEM remote command and variables related Flow Rate Calibration process.
Table F.17-1 Flow Rate Calibration Remote Command Collection Events
Collection Event Name CEID
Related Data
and Status
Variables
Description
Remote Command String =
“FLOWRATECALIB”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
Valve 1 = 400
Valve 2 = 403
Status = 640
Remote control command to start Flow Rate Calibration. When a DJ
valve is used, this command will perform the Calibrated Process Jetting
routine. (mg/dot flowrate) The valve flow rate is changed to the new
calibrated value.
3730 ce_FlowRateCalibComplete_V1Pass
3731 ce_FlowRateCalibComplete_V2Pass
3784 ce_FlowRateCalibComplete_V1Fail
3785 ce_FlowRateCalibComplete_V2Fail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.