Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-59
F.23 Needle Z OffsetsRemote Command
Needle Z Offsets is a script command used during machine setup calculate the Z offset of the Needle/Jet relative to the height sensor origin. The
SECS/GEM host can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM remote command
and variables related Needle Z Offsets.
Table F.23-1 Needle Z Offsets Remote Command
Remote Command CEID
Related Data and
Status Variables
Description
Remote Command String =
“NEEDLE Z OFFSETS”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
6294 Remote control command to start Needle Z Offsets
3738 ce_NeedleZOffsetsPass
3786 ce_NeedleZOffsetsFail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.
Needle Z Offsets
Table F.23-2 Needle Z Offsets Equipment Constants
Variable Name ID
Storage
Type
SECS
Type
CEID Description
c_ZNeedleOffset_V1 6294 A40 EC 3738 Needle Z offset for Valve 1.