Owner's manual

SECS Message Detail 4-11
4.2.16 S2F13 - Equipment Constant Request
S2F13 W * H->E
<L
<U4 VID> * Equipment Constant ID
...
> .
The Host requests the VIDs of interest. Several VIDs can be specified if desired.
Normally, only VIDs of class EC (i.e. equipment constants) are used in this message. However, any VID
of class DV, EC, or SV can be used.
If S2F13 contains a zero-length list, then the Equipment will report all variables of class EC, in order by
VID.
For compatibility with older Host implementations, the Equipment allows the following alternative form
for this message, using an array format:
S2F13 W * H->E
<U4 VID VID ...> . * Equipment Constant ID
4.2.17 S2F14 - Equipment Constant Data
S2F14 * H<-E, Multiblock
<L
<V> * Equipment Constant Value
...
> .
The Equipment returns the equipment constants in the order requested in S2F13. If any VID specified in
S2F13 is invalid, the corresponding V in S2F14 has the following error format:
<L> * V for Invalid VID