User Manual
Maintenance 7-5
7.8 Cleaning the Fluid Filter
WARNING! CAUTION!
Follow MSDS recommendations for the proper handling and disposal of all
materials when cleaning the fluid filter. Always wear appropriate personal
protective equipment (PPE) as recommended by facility safety practices and the
material manufacturer’s MSDS. To prevent eye injury or irritation, wear safety
goggles while performing this procedure.
To clean the fluid filter:
1. Turn the Reservoir Air Pressure Switch to the
OFF (0) position. See Figure 7-3.
2. Relieve residual pressure in the fluid system by opening the pressure relief valve on the
fluid reservoir.
Figure 7-3A Coating System Rear Panel
Figure 7-3B Fluid Reservoir
Item Description
1 Reservoir Air Pressure Switch (right rear)
2 Fluid Reservoir Pressure Relief Valve
Figure 7-3 Relieving the Air Pressure
1
2