2.10.1 Emergency Shutdown Situations
As a minimum, activate the EMO in the following situations:
WARNING! CAUTION!
In an emergency, failure to completely shut down power to the coating system with
the EMO can cause serious injury to the user and/or damage to the coating system.
• If anyone is in immediate danger of being injured by moving parts, hazardous materials, or
electrical shock.
• If valuable coating system components or the workpieces are in danger of being damaged.
This can include:
- Physical damage to the dispensing valve or workpiece by unexpected dispensing
head movement.
- Electrical damage to the coating system.
2.10.2 Emergency Shutdown Recovery
WARNING! CAUTION!
Do not restart the dispensing operation until the condition that caused the
emergency shutdown has been corrected. Failure to comply could cause serious
injury to the user and/or serious damage to the coating system.
NOTE If the Main Circuit Breaker has been tripped, you will need to restart the coating system
as specified in 4.7 Powering On the System.
To recover after an emergency shutdown:
1. Open the hood and clear the conveyor of all workpieces.
2. Locate and remedy the cause of the emergency shutdown. If necessary, refer to Section 8 -
Troubleshooting.
3. Close the front hood.
4. Turn the EMO knob clockwise until it pops back into position.
5. Press the
Start (I) button on the front panel.
6. Restart your dispensing program. See 5.17 Loading a Program and 5.18 Running a
Program.