User Manual

3-6 Installation
3.5 Leveling the Coating System
WARNING! CAUTION!
This procedure should only be performed by a trained service technician. The
system should be shutdown for service before performing this procedure. Refer to
5.11.2.4 Service Shutdown.
1. Place a box level on the conveyor rail along the X-axis (Figure 3-5).
2. Observe the position of the bubble within the level’s window.
The bubble should be centered, indicating the coating system is level from side-to-side.
Figure 3-5 Leveling the Coating System – X-Axis
3. If necessary, adjust the levelers (Figure 3-6) of the coating system as follows:
a. Loosen the 1 1/2-inch lock nut on the leveler if necessary.
b. Turn the 1 1/2-inch post nut in the desired direction until the level’s bubble is centered,
indicating that the system is level from side-to-side.
Turning the post nut clockwise raises the coating system. Turning the post nut
counterclockwise lowers the coating system.
Item Description
1 Lock Nut
2 Post Nut
3 Leveler
Figure 3-6 Coating System Levelers (Feet)
1
2
3