User Manual
4-12 Power-up and Testing
To check the function of the Conveyor Air Regulator and Gauge:
1. Locate the Conveyor Air Regulator adjustment knob inside the rear cover of the coating
system (Figure 4-9).
2. With the Main Air Pressure ON, check the gauge reading. It should read 276 kPa ± 28 kPa
(40 psi ± 5 psi).
3. If the Conveyor Air Regulator needs adjustment, loosen the jam nut to unlock the regulator.
4. Rotate the regulator counterclockwise until the Conveyor Air Gauge registers zero (0).
5. Rotate it clockwise until the Conveyor Air Gauge registers 276 kPa (40 psi).
6. When the desired air pressure is set, tighten the jam nut on the Conveyor Air Regulator.
Item Description
1 Stop/Clamp Air Gauge
2 Stop/Clamp Air Regulator
Figure 4-9 Conveyor Air Regulator and Gauge
1
2