User Manual
Power-up and Testing 4-17
4.14 Conveyor Function
To check function of the Conveyor:
1. Load a sample workpiece (included in the accessories crate) onto the conveyor port.
If necessary, adjust the distance between the conveyor rails to fit the sample workpiece.
Refer to 5.7 Conveyor Operations.
2. Select
Edit > Edit Mode from the ECXP Operator Screen to access the ECXP Edit Screen.
3. Select
Utilities > Conveyor Utilities > IO Tool from the menu bar (Figure 4-13).
Figure 4-13 ECXP Edit Screen - Conveyor Utilities
4. Locate the I/O labeled Left Sense (Figure 4-7).
5. Manually move the workpiece under the Board Sensor.
6. Watch the Left Sense bit in the I/O Test dialog box and make sure that it toggles
ON and
OFF as the workpiece passes under the sensor.
If the bit does not toggle ON and OFF, the sensor location may need to be adjusted.
Refer to Section 8 - Troubleshooting.
7. Repeat Steps 5 through 6 for each Board Sensor on your coating system.
8. Click on
Utilities > Conveyor Utilities > Load Board.