5.10.1 Main Air Regulator and Gauge
The Main Air Inlet provides regulated air pressure to the coating system from your facility air source.
You can adjust the main air pressure with the Main Air Regulator. The recommended pressure from the
facility air supply to the coating system is 586 to 620 kPa (85 to 90 psi).
To adjust the main air pressure:
1. Verify that the facility air supply is connected to the Main Air Inlet.
2. Locate the Main Air Regulator at the rear of the coating system (Figure 5-4).
TIP For accurate pressure adjustment, lower the pressure below the desired level and then
increase to the desired pressure.
3. Rotate the Main Air Regulator counterclockwise until the Main Air Gauge registers
zero (0).
4. Rotate it clockwise until the Main Air Gauge registers 586 to 620 kPa (85 to 90 psi).
If the Main Air Gauge fails to register pressure, verify that the coating system is
connected to the facility air source.
If there is an air leak, identify the source, shut off the facility air, and fix the leak before
proceeding.
NOTE The regulator assembly is equipped with a relief valve to protect the system
components. Increasing the pressure above 655 kPa (95 psi) may trigger the relief
valve. If so, reduce the air pressure below 655 kPa.
Item Description
1 Main Air Regulator
2 Main Air Gauge
3 Main Air Inlet
Figure 5-4 Adjusting Main Air Pressure
3