Furnace User Manual

31
Table 10. M1/M5 Furnace Specifi cations - Factory Settings
Furnace
Model No
Input
MBtu/h
Output
MBtu/h
Orifi ce No
E.S.P.
In WC
Pilot
Burner
Ignitor
Direct
Comb.
Blower
Motor
Hp
A/C Ready
Tons
Nat. LP
M1GB 056 56 45 29 45 0.3 x 1/4 3
M1GB 070 70 57 24 42 0.3 x 1/4 3
M1GB 077 77 62 21 40 0.3 x x 1/4 3
M1GB 090 90 72 17 36 0.3 x x 1/4 3
M1MB 056 56 46 29 45 0.3 x x 1/4 3
M1MC 056 56 46 29 45 0.3 x x 1/2 4
M1MB 070 70 57 24 42 0.3 x x 1/4 3
M1MC 070 70 57 24 42 0.3 x x 1/2 4
M1MB 077 77 62 21 40 0.3 x x 1/4 3
M1MC 077 77 62 21 40 0.3 x x 1/2 4
M1MB 090 90 72 17 36 0.3 x x 1/4 3
M1MC 090 90 72 17 36 0.3 x x 1/2 4
M1BB 066 66 53 26 43 0.3 x x 1/4 3
M1BC 066 66 53 26 43 0.3 x x 1/2 4
M1BB 086 86 68 18 37 0.3 x x 1/4 3
M1BC 086 86 68 18 37 0.3 x x 1/2 4
M5SB 066 66 56 .50 Gph 0.3 x Burner Model: 1/4 3
M5SC 066 66 56 .50 Gph 0.3 x AF-10 1/2 4
M5SB 086 86 73 .65 Gph 0.3 x Spray Angle: 1/4 3
M5SC 086 86 73 .65 Gph 0.3 x 80° A 1/2 4
NOTES:
Electrical Supply - 120 volts, 60HZ, 1 Ph.
Fuse or Breaker - 15 amps
Temperature Rise - 45° F to 75° F
High Altitude - See Table 12 (page 32). For
Canadian Altitudes (2,000’ to 4,500’), reduce the
gas manifold pressure to 3.0” W.C. for natural gas
and to 8” W.C. for LP gas.
Thermostat Circuit - 24 volts, 60HZ, 30 vac
Normal Anticipator Setting - 0.4
Manifold Pressure - Natural Gas: 3.5” w.c.
LP Gas: 10” w.c.
FIGURES & TABLES