Instructions / Assembly

13
* Do not change any other dip switches.
High Elevation Adjustment
Dip Switches
#6#5
2,001 - 4,000 ft (611 - 1,220m)
0 - 2,000 ft (0 - 610m)
ON=OFF=
4,001 - 7,000 ft (1,221 - 2,135m)
7,001 - 10,000 ft (2,136 - 3,050m)
Elevation Adjustment Above 2,000ft
Typical plumbing (Direction of the isolation valve)
Adjust the dip switches as illustrated in the table to the below if this water heater is installed at an altitude of
2000 ft. (610m) or higher.
• Disconnect power to the water heater before changing the dip switches.
Failure to perform this step will result in a "73" code displayed on the remote controller and a cease in operation.
If this occurs, disconnect, then reconnect power to the water heater to reset the system.
Note : Please refer to page 28 for the location of the dip switch bank.
Filling the condensate container with water
The condensate container can be lled before connecting the vent pipe.
Filling the condensate container before vent pipe installation.
DANGER
Prior to initial start up, make sure that you ll the condensate container with water.
This is to prevent dangerous exhaust gases from entering the building.
Failure to ll the condensate container could result in severe personal injury or
death.
Please follow one of the procedures described below to ensure that the condensate container is lled with water.
1) Fill the condensate container by pouring
approx. 10 oz.(280ml) of water into the exhaust accessory
on the top of the appliance as illustrated below.
Or, if the vent pipe has already been installed:
2) After installing the drain pipe, make sure that the area around the appliance is well ventilated; open a
window or a door if necessary.
Then, operate the unit and verify that condensate is coming out of the drain pipe.
(During normal use of the water heater, condensate will begin to discharge from the drain pipe within
15 minutes of use. However, depending on the season and/or installation site conditions, it may take longer.)
10 oz.
280ml
Intake
Exhaust
Pressure Relief V
alve
Intake Pipe Exhaust Pipe
Water Drain Valve
(with Water Filter)
Water Supply Valve