Use and Care Manual

14
Cooking Equipment
When utilizing an indoor air supply, if the Water
Heater will be installed in the vicinity of a
permanent kitchen range or stove that has the
possibility of generating steam that contains fats
or oils, use a dividing plate or other measure to
ensure that the Water Heater is not exposed to air
containing such impurities.
Exhaust hood
Range
The dividing pla
te should
be of non-combus
tible
material of a width
gr
eater than the Water
Heate
r.
4.2 Outdoor Installation
Required Clearances From the Water Heater
Maintain the clearances from both combustible and
non-combustible materials.
24 in. (610 mm)
or more
36 in. (910 mm)
or more
Outdoor Vent Cap
(VC-6)
3 in. (76 mm) or more
4.3 For Quick Connect Multi-System
Surrounding the area of installation
[
When installing the Water Heater in a common side
corridor
]
47 in. (1,194 mm)
or more
84 in. (2,134 mm)
or more
the bottom edge of
the exhaust port
Common side
corridor
Handrail
The Quick Connect Cord is 6 ft (1.8 m) long.
Install the Water Heaters 3-18 in. (76-457 mm)
apart from each
other to ensure the cord will be able
to reach between the Water Heaters.
3-18 in.
(76-457 mm)
Installation Clearances