Use and Care Manual

53
Installation
1. Attach the Mounting Bracket to the wall. The parts to be used vary depending on the attachment method.
Mounting Bracket
(included part)
Junction box
Flat Head Machine
Screw
(included part)
Confirm the
orientation of the
Mounting Bracket
is correct.
Top
Bottom
[When attaching to a junction box]
Use the Flat Head Machine Screws to attach the
Mounting Bracket to the junction box.
(The Dry Wall Anchor and Flat Head Tapping
Screws are not used.)
Mounting Bracket
(included part)
Flat Head Tapping
Screw
(included part)
Confirm the
orientation of the
Mounting Bracket
is correct.
Top
Bottom
[When attaching to a wood surface]
Use the Flat Head Tapping Screws to attach the
Mounting Bracket.
(The Dry Wall Anchor and Flat Head Machine
Screws are not used.)
NOTE
Never use electric drivers, impact drivers, etc. Tightening with excessive force may result in
deformation of the Mounting Bracket and/or failures.
Mounting Bracket
(included part)
Dry Wall Anchor
(included part)
Flat Head Tapping
Screw
(included part)
Confirm the
orientation of the
Mounting Bracket
is correct.
Top
Bottom
[When attaching to a concrete wall surface]

in. (25 mm) in depth, and hammer in the Dry
Wall Anchor.
Attach the Mounting Bracket using the Flat Head
Tapping Screws.
(Flat Head Machine Screws are not used.)
NOTE
Too large hole for Dry Wall Anchor
may result in failure to properly
secure the Remote Controller.
Installation of the Remote Controller