Replacement Parts List

707
731
G
179
706
C
F
179
700
072
707
731
072
701
708
702
709
N
179
E
179
705
EXS
ElectroniccontrolunitNRC663-FSV
ElectroniccontrolunitNRC663-FSV
PartNos. PartNames OrderNos. Q'ty/unit
700 CircuitBoard SKJ70WT 1
701 CircuitBoard SHC701M 1
702 Cover-CircuitBoard EXSA022 1
705 WiringHarness-NRC663-FSV SKJ70WU 1
706 PowerSupplyCord ERUJ001 1
707 WireClamp-Nylon 7287909 2
708 Label-CircuitBoardPlasticCover EVPK006 1
709 MountingPlate-CircuitBoard EXSA021 1
731 Screw-RemoteTerminalCoverM4X12S410
750
761
762
752
751
x2
x2
760
803
802
x5
Remotecontroller,AttachedsetNRC663-FSV
Attachedset
Specialpart Specialpartno.
<Specialpart>
Owner'sguide
888
Installationmanual
889
Optional
Remotecontroller
RC-7651M-ENG
Remotecontroller,AttachedsetNRC663-FSV
PartNos. PartNames OrderNos. Q'ty/unit
750 RemoteController-RC-7651M(SET) QXUJ017 1
751 Cover-Remote QMEA003 1
752 MountingPacking-Remote QHUA115 1
760 ScrewPackage-Remote(SET) QQUA100 1
761 Screw-RoundHeadWoodM4.1X25S305
762 DryWallAnchors6X25
800 Box-NRC663-FSV SKJ70WV 1
Label-GasTypeLP ESCK008 1<LP>
802 WoodScrewset5 SAF6007 1
803 Screw-RoundHeadWood4.8X38S305
888 Owner'sGuideNRC663-FSV SBB809K 1
889 InstallationManualNRC663-FSV SBB809L 1
(RIGHT SIDE)
Thermal Fuse Installation Procedure
(BACK)
Install the thermal fuse following the below procedure.
1. Begin the installation by attaching the thermal fuse to the right side
of the heat exchanger.
2. Bend the thermal fuse to the back of the heat exchanger and fixing
the thermal fuse by the fastener at attachment point 1 as indicated
in the above illustration.
3. Continue wrapping the thermal fuse around the heat exchanger
securing it at each attachment point using the fasteners shown in
the above illustrations.
Caution
The thermal fuse may snap if it is twisted,
pinched or bent too sharply.
Do not bend the thermal fuse to a radius of
less than 1.25".
Freeze Prevention Heater Installation Procedure
Please check the present position and re-install to the original position.
Install the freeze prevention heater according to following illustrations.
(LEFT SIDE)(FRONT)
Procedure for Flushing the Heat Exchanger
If the error code “C #*~C #*” is flashing on the Display Window, it means there is Scale Build-up
in the Heat Exchanger.The Heat Exchanger needs to be flushed** to remove the Scale Build-up.
Damage to the water heater due to Scale Build-up is not covered by the water heater's warranty.
To clear the error code “C
#*~C #*”, the Heat Exchanger
If the error code “C #*” is displayed and flashing in the Display Window, please contact Noritz
America (866-766-7489).
* = 1, 2, 3, 4, F
# = 1, 2, 3, 4, 5, 6, 7, 8, 9, A, b, C, d, E, F
** Connect the “blue connector” for flushing on the Circuit Board when flushing the Heat Exchanger.
After connecting it, the water heater is set to “Flushing Mode”.
㻥䋱㪅㩷The preparation of the flushing system
1. Close the gas supply valve.
2. Close the water inlet valve (V1) and the water outlet valve (V2).
3. Connect the one drain hose (H1) to the drain valve (V3), and then the other to the circulating
pump.
4. Connect the drain hose (H2) to the circulating pump.
5. Connect the drain hose (H3) to the drain valve (V4).
6. Pour 4 gallons or more of flushing solution*** into the bucket.
*** Noritz recommends “White Vinegar”.
7. Place the both drain hoses (H2 and H3) into the bucket filled with the flushing solution.
H3
H1
Water Heater
Display Window
Bucket
Flushing
Solution
Circulating
Pump
㻥䋳㪅㩷Cleaning the Heat Exchanger
The flushing solution needs to be rinsed and cleaned out of the water heater.
Below is the way to rinse and clean the flushing solution.
1. Remove both drain hoses (H2 and H3) from the bucket. And then place the drain hose (H3)
into the sink or outside to drain.
2. Close the drain valve (V3) and then open the water inlet valve (V1).
Do not open the fresh water outlet valve (V2).
3.
Clean the water heater with fresh water for 3 minutes or more.
(Needs to have enough time to clean the water heater.)
4. Close the drain valve (V4) and then remove the drain hose (H3)
from the drain valve (V4).
5. Remove the drain hose (H1) from the drain valve (V3).
6.
Disconnect the “blue connector for flushing” on the Circuit Board.
The code
“C00” goes out on the Data Display.
7. Close the Front Cover.
8. Open the gas supply valve and water outlet valve (V2).
9 Check for correct operation of the water heater.
H2
Detects the flow
1 minute passes
The water heater must remain connected to electrical power
when flushing the Heat Exchanger.
㻥䋲㪅㩷Flushing the Heat Exchanger
1. Open the Front Cover.
2. Connect the
“blue connector*****” for flushing on the Circuit Board.
3. Then the code
“CCC” is displayed on the Data Display.
4. Turn on the circulating pump to circulate the flushing solution through the water heater
for 1 hour at a rate of 1.5 gallons per minute or more.
5. The code
“C60” is displayed on the Data Display when the water heater detects the flow of the
flushing solution.
When 1 minute passes, the code
“C60” will change to “C59” on the Data Display.
6. When 1 hour passes, the code
“C00” is flashing on the Data Display.
Do not disconnect the “blue connector for flushing” on the Circuit Board.
7. Turn off the circulating pump.
*****The connector is located behind
the Circuit Board Plastic Cover.
The connector color is blue and
labeled “FLUSH”.
Data
Display
Please check whether the reverse connection of the hose (H1) and (H3) if the display number will not change.
In that case, the flow rate of the flushing solution may be under 1.5 gallons per minute.
Flashing
The water heater can not operate
if the “blue connector” for flushing is
connected.
**** Isolation valves may be purchased as an accessory from
㩷㪸㫅㩷㪸㫌㫋㪿㫆㫉㫀㫑㪼㪻㩷㪥㫆㫉㫀㫋㫑㩷㫎㪿㫆㫃㪼㫊㪸㫃㪼㫉 .
They allow for full diagnostic testing and easy flushing of the system.
Contact Noritz America for more information (866-766-7489).
FLUSH
Connect
Disconnect
FLUSH
Please contact Noritz America if more information is needed for flushing.
(Phone # : 866-766-7489)
This procedure is only intended for use by a qualified service professional or authorized Noritz
Service Representative. Any unauthorized use of this procedure may result in voiding the
warranty.Please contact Noritz America (866-766-7489) for additional support.
Isolation valves**** are necessary for
flushing the Heat Exchanger.
V1
V3
V4
V2
Gas Supply
Gas Suppy Valve
Continue to connect
Water
Inlet
Water
Outlet
V1
V2
V3
V4