Problems What to do
Display Window
The hot water at the
xture is too hot.
Are the gas and water supply valves fully open?
[Using the optional remote controller]
Is the water temperature setting appropriate? (page 13)
[Using the optional remote controller]
If the water supply temperature is high, it is possible
for the
outlet
temperature to be higher than the
temperature set on the remote controller.
[Using the optional remote controller]
If only a low ow of hot water is demanded, it is
possible for the outlet temperature to be higher than the
temperature set on the remote controller.
The hot water at the
xture is not hot enough.
Are the gas and water supply valves fully open?
[Using the optional remote controller]
Is the water temperature setting appropriate? (page
13)
If the amount of hot water required is very high, it is
possible for the
outlet
temperature to be lower than the
temperature set on the remote controller.
Decrease the amount of hot water passing through the
unit and the temperature should stabilize.
The actual outlet water temperature is lower than the set
temperature of the unit.
Contact the nearest Noritz agent.
The water is cold when only
a single xture is open.
The unit will not heat the water if the ow rate is less
than 0.5 gallons (2L) per minute.
Open the xture more or open other xtures so that
a greater ow passes through the unit, and the unit
should begin heating again.
The unit does not re when
water is owing due to high
supply water temperature.
If you try to supply a low ow of water when the supply
water temperature is too high.
The unit will not re because it will over heat the outlet water.
Fluctuations in hot water
temperatures.
Clean the water lter of any debris. (page 22)
[Using the optional remote controller]
Setting temperature cannot rise.
Is the maximum temperature setting appropriate? (page 15)
Troubleshooting-2