Use and Care Manual
26
Drain Plugs
Each drain plug might not be visible if
insulation is installed around the piping.
If the Combi Boiler will not be used for a long period of time, drain the water.
Drain the water as follows:
To avoid burns, wait until the equipment cools down
before draining the water. The appliance will remain
hot after it is turned off.
High Temperature
CAUTION
4
Open all drain plugs and drain the water out of
the unit.
1
Fully open all hot water
xtures/faucets.
Drainage Using the Operation Panel
2
(1) Turn the power button on.
(2) Turn and leave open
the hot water xtures/
faucets
for more than
2 minutes
and close.
* If multiple units are being used,
drain two minutes for each unit.
* An 11 Error Code may appear on
the Operation Panel.
This is not a malfunction of the unit.
Do not turn the power button off.
Manual Draining
Close the water supply valve
and disconnect the electrical
power supplied to the unit.
3
4
5
When the screen display turns off, replace all
drain plugs and close the hot water fixtures/
faucets.
5
Open all drain plugs and drain the
water out of the unit.
6
Close the gas valve.
1
Close the water supply valve and
the auto feeder shutoff valve.
( p. 8)
2
When the water is completely drained,
replace all drain plugs and close the
hot water xtures/faucets.
Do not touch with wet hands.
Drain water into a bucket to prevent water damage.
(1) Press the button OFF.
The Operation Panel must be off.
(2)
Press the button, Select
using the buttons. Press the button.
The "User Mode" screen appears.
(3) Select using the buttons,
and then press the button.
(4) Press and hold the
button approximately
2 seconds to turn "ON".
( Refer to page 21 for details.)
6
Close the gas valve and disconnect
the electrical power supplied to the unit.
Do not touch with wet hands.
Fully open all hot water
xtures/faucets.
3
Hot water
xture/faucet
Hot water
xture/faucet
Hot water
xture/faucet
To prevent damage from freezing, the Combi Boiler must be plugged into power at all times. If power is unplugged, drain the
water completely from the Combi Boiler. Then use an air compressor to remove all water from inside the unit's water piping.
It is recommended that Isolation Valves are installed on the Combi Boiler, otherwise the water connections will need to be
removed to drain the unit completely. Freeze damage due to not draining properly will not be covered under warranty.
After 1 sec.
(drA:Drain The Water)
(1) Press the button OFF.
䍾
Lid - Condensate Container
䍿
䚷㻌Do not take the lid off.
Preventing Damage from Freezing-2