Use and Care Manual

35
The water appears blue
The bath tub/wash-basin has turned
blue
Coloration to a blue color may be noticed from small
traces of copper ion contained in the water and fat
(furring). However, there are not problems concerning
health. Coloration of the bath tub/wash-basin can be
prevented by cleaning frequently.
Frequent water discharge from the
drain pipe.
Condensation forms inside the unit during operation
and is discharged from the drain pipe.
The Combi Boiler stops burning
during operation.
Are the gas and water supply valves fully open?
Is the water supply cut off?
Is the hot water xture/faucet sufciently open?
Is the gas being cut off by the gas meter?
(Can other gas devices such as stoves be used?)
(For LP) Is there enough gas in the tank?
(Can other gas devices such as stoves be used?)
When the heating supply temperature is too high, the unit
will stop burning.
This is normal. The white smoke is actually steam.White smoke comes out of the
exhaust vent on a cold day.
The DHW is turbid.
This is harmless. Small bubbles appear as the air in the
water is heated and depressurized rapidly to
atmospheric pressure.
Other
A small amount of water is discharged
from the pressure relief valve.
This is normal. When the Combi Boiler is under high
pressure, a small amount of water may be discharged
from the pressure relief valve.
There is a possibility that air is leaking from the expansion
tank. Contact your installer or a qualified service technician.
When DHW Wait Time is operating, the screen display
occasionally shows
This is normal. This shows disconnecting the outdoor sensor.
( p.16)
The Combi Boiler water is leaking
from the safety relief valve.
The screen display shows
(The Burner ON Icon is lit without
DHW Icon or Heating Icon.)
.
.
is
blinking