NR83 Installation Manual

4
4.
Before Installation
Checkup
Check the xing brackets and vent pipe yearly for damage or wear. Replace if necessary.
DANGER
Do Not Use Equipment for Purposes Other Than Those Specied
Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
Check that the rating plate indicates the
correct type of gas.
Check that the gas supply line is sized for
180,000 Btuh for this unit.
Check the Power
The power supply required is 120VAC, at 60Hz.
May result in re or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
Precautions on Vent Pipe
This appliance requires the use of special concentric type vent pipe specied by Noritz America.
Do not attempt to use materials that are not specied for use on this appliance.
Improper venting may result in a re, property damage, or exposure to Carbon Monoxide.
Snow Precaution
If this product will be installed in an area where snow is known to accumulate, protect the vent termi-
nation from blockage by snow drifts or damage from snow falling off of roofs.