NR83 Owners Manual

28
Specications
•Specicationsmaybechangedwithoutpriornotice.
•Thecapacitymaydifferslightly,dependingonthewaterpressure,
watersupply,pipingconditions,andwatertemperature.
Specication
NR83-DVC
IndoorWallMounted
PowerVented
DirectIgnition
15-150psi
0.5GPM(2L/min.)
23.6"(600mm)x13.8"(350mm)x9.4"(240mm)
49lbs.
0.2Gallon(0.95L)
3/4"
3/4"
3/4"
120VAC(60Hz)
NG:82WLP:90WFreezePrevention161W
ZinciedSteelPlate/PolyesterCoating
StainlessSteel
CopperSheeting,CopperTubing
FlameRod,ThermalFuse,LightningProtection
Device(ZNR),OverheatPreventionDevice,Freezing
PreventionDevice,FanRotationDetector
AnchoringScrews
Specications
Performance
Item
ModelName
Type
Ignition
OperatingPressure
MinimumFlowRate
Dimensions(Height)x(Width)x(Depth)
Weight
WaterHoldingCapacity
Accessories
Installation
AirSupply/Exhaust
ConnectionSizes
PowerSupply
Materials
WaterInlet
HotWaterOutlet
GasInlet
SafetyDevices
Item
Gas
Consumption
MaximumHotWaterCapacity
CapacityRange
TemperatureSettings
DefaultTemperatureOptions
NG
LP
45°F(25°C)Rise
MaximumPerformance
180,000btuh
180,000btuh
MinimumPerformance
18,000btuh
18,000btuh
6.7GPM(25.4L/min.)
0.5-8.3GPM(2-31.4L/min.)
100-140°F(In5°Fintervals)(9Options)
50,55,60°C(Originalis50°C)
Casing
FlueCollar
HeatExchanger
Supply
Consumption
120,130,140°F(Originalis120°F)
°FMode:
°FMode:
°CMode:
°CMode:
37-48°C(In1°Cintervals),
50,55,60°C(In5°Cintervals)(15Options)