Gas Conversion
If you move to a region that uses a different type of gas or if the local gas supply is converted,
replacement of the gas manifold and adjustment of the appliance will be necessary.
This work must be performed by either Noritz or a qualied service agency and will be charged for
even during the warranty period. The qualied installer will also be responsible for purchasing the
gas conversion kit directly from the manufacturer.
For more information, contact Noritz America Technical Support at 866-766-7489.
The following parts are supplied in the conversion kit. These items will replace the existing parts that
are currently installed in the unit. Make sure that all parts are replaced and properly installed by a
qualied service agency.
* A Noritz remote controller and a digital gas manometer are required to complete the installation.
Do not proceed if this equipment is not immediately available.
* A qualied service agency is any individual, rm, corporation, or company which either in person or through
a representative is engaged in and is responsible for the connection, utilization, repair or servicing of gas
utilization equipment or accessories; who is experienced in such work, familiar with all precautions required,
and has compiled with all of the requirements of the authority having jurisdiction.
The gas conversion kit shall be installed by a qualied service agency* in accordance with
the manufacturer’s instructions and all applicable codes and requirements of the authority
having jurisdiction. The information in the instructions must be followed to minimize the risk
of re or explosion or to prevent property damage, personal injury, or death. The qualied
service agency is responsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is checked as specied in
the manufacturer’s instructions supplied with the kit.
Before the gas conversion is performed, verify the proper gas conversion kit with your
water heater model on the table provided below.
After the necessary parts have been replaced on the unit, the remote controller is then used to adjust
the settings on the water heater for use with the proper gas type.
The following pressure value are veried by the installer.
-The inlet gas pressure value at the gas supply inlet tting
-The offset pressure value at the gas valve
Proper adjustments will be made to ensure safe and efcient operation.
Once this is completed, a nal gas leak check will be performed to conrm that all parts have been
securely installed.
If you notice the smell of gas at any time after the installation has been completed, turn the water
heater off and contact your gas supplier immediately.
Venturi Mixer Set
O-Ring × 2
Conversion Kit Label
WARNING
Follow-up Service-2
Conversion Kit Model Conversion Type
CK-75
EZ111DV (GQ-C3259WX-FF US)
Propane to Natural Gas
CK-76 Natural Gas to Propane
CK-77
EZ98DV (GQ-C2859WX-FF US)
Propane to Natural Gas
CK-78 Natural Gas to Propane