Brochure

Headquarters • 11160 Grace Avenue, Fountain Valley, CA 92708 • Fax: (714) 241-1196
Atlanta • 1220 Kennestone Circle, Suite 126, Marietta, GA 30066 • Fax: (770)422-0184
Chicago • 861 Busse Road, Elk Grove Village, IL 60007 • Fax: (847) 472-6885
Dallas • 720 Industrial Boulevard, Suite 200, Grapevine, TX 76051 • Fax: (817) 421-0033
New York • 12 Skyline Drive, Hawthorne, NY 10532 • Fax: (914) 345-3288
Showroom
Locations
www.noritz.com/commercial
Toll Free: (877) 511-4328
2010 JANUARY © 2010 Noritz America™Corporation. All rights reserved.
29.7” (H) x 19.1” (W) x 11.8” (Depth)
105 lbs.
Max. 380,000 Btuh- Min. 22,500 Btuh
Max. 380,000 Btuh- Min. 22,500 Btuh
0.7-13.2 Gal./min.
80% (NG), 84% (LP)
100-150˚F (in 5˚F Intervals), 160, 170, 181.4˚F
Remote Control& Cord, Anchoring Screws
Thermal Eciency
Temperature Outputs
Included Accessories
Dimensions
Weight
NG
LP
Gas Consumption
Capacity Range
84%
EFFICIENCY
NC380 ASME Series
max temp setting: 180˚•
temp settings: 100-180˚ •
0.7 min gpm- 13.2 max gpm •
534 GPH at 70˚ temperature rise •
NSF & ASME certified •
stainless steel casing •
2-unit quick-connect •
up to 24-unit multi-system •
Commercial-Grade
Vent Options
SV
SV Unit: 24.2” (H) x 18.3” (W) x 9.4” (Depth)
DV Unit: 24.4” (H) x 18.4” (W) x 9.4” (Depth)
73 lbs.
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
SV Unit: 93%, DV Unit: 93.3% (NG), 93.9% (LG)
Remote Control & Cord, Anchoring Screws,
Condensate Neutralizer
Thermal Eciency
Temperature Outputs
Included Accessories
Dimensions
Weight
NG
LP
Gas Consumption
Capacity Range
100-150˚F (in 5˚F Intervals), 160, 170, 181.4˚F
max temp setting: 180˚•
temp settings: 100-180˚ •
0.5 min gpm- 11.1 max gpm •
318 GPH at 70˚ temperature rise •
stainless steel casing •
2-unit quick-connect •
up to 24-unit multi-system •
94%
EFFICIENCY
Vent Options
NCC199 Series
Commercial-Grade
PVC
V
E
N
T
I
N
G
Z
E
R
O
C
L
E
A
R
A
N
C
E
DV
SV
Condensing
24.4” (H) x 18.4” (W) x 9.4” (Depth)
62 lbs.
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
84%
100-150˚F (in 5˚F Intervals), 160, 170, 181.4˚F
Remote Control & Cord, Anchoring Screws
Thermal Eciency
Temperature Outputs
Included Accessories
Dimensions
Weight
NG
LP
Gas Consumption
Capacity Range
NC250 ASME Series
max temp setting: 180˚•
temp settings: 100-180˚ •
0.5 min gpm- 11.1 max gpm •
360 GPH at 70˚ temperature rise •
NSF & ASME certified •
stainless steel casing •
2-unit quick-connect •
up to 24-unit multi-system •
84%
EFFICIENCY
Commercial-Grade
Vent Options
DV
SV
DVC Unit: 23.6” (H) x 13.8” (W) x 10.2” (Depth)
OD Unit: 23.6” (H) x 13.8” (W) x 9.4” (Depth)
DVC Unit: 55 lbs. OD Unit: 47 lbs.
Max. 199,900 Btuh- Min. 12,000 Btuh
Max. 199,900 Btuh- Min. 12,000 Btuh
0.5-9.8 Gal./min.
84%
100-150˚F (in 5˚F Intervals),160, 170, 181.4˚F
Remote Control & Cord, Anchoring Screws
Thermal Eciency
Temperature Outputs
Included Accessories
Dimensions
Weight
NG
LP
NC199-OD
Gas Consumption
Capacity Range
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
NG
LP
NC199-DVC
Gas Consumption
NC199 Series
max temp setting: 180˚•
temp settings: 100-180˚ •
0.5 min gpm- 9.8 max gpm •
288 GPH at 70˚ temperature rise •
2- unit quick-connect •
up to 6-unit multi-system •
84%
EFFICIENCY
Vent Options
Commercial-Grade
OD
DVC
40˚ 50˚ 60˚ 70˚ 80˚ 90˚ 100˚ 11 120˚ 13
GPH 380,000 792 750 624 534 468 414 372 342 312 288
GPM 380,000 13.2 12.5 10.4 8.9 7.8 6.9 6.2 5.7 5.2 4.8
GPH 250,000 630 504 420 360 318 282 252 228 210 192
GPM 250,000 10.5 8.4 7 6 5.3 4.7 4.2 3.8 3.5 3.2
GPH 199,900 558 444 372 318 276 246 222 204 186 174
GPM 199,900 9.3 7.4 6.2 5.3 4.6 4.1 3.7 3.4 3.1 2.9
GPH 199,900 504 402 336 288 252 222 204 183 168 156
GPM 199,900 8.4 6.7 5.6 4.8 4.2 3.7 3.4 3.05 2.8 2.6
NC380-SV-ASME
NC250-DV-ASME
NCC199-DV
NC199-DVC
Model Number
Flow
BTU Input
Temperature Rise