Install Instructions

3
G
Quick Connect
Cord
Remote Controller Cord
Gas Supply Piping
Cold Water Supply
Hot Water
Remote Controller
Terminal Block
Cord
Connector
Cord
Connector
3.
Quick Connect Multi System Installation
The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
Typical Plumbing
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
System Diagram
Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the
cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively
cold temperatures.
Union
Make this distance as short as possible.
* The hot water temperature will
become unstable as the pipe
length increases.
Quick Connect
cord
Union
Gas Valve
Union
Shutoff
Valve
Shutoff Valve
Hot Water
Cold Water
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
Pressure
Relief
Valve
Shutoff Valve
Size the piping to allow for the
maximum flow rates of the units.
The backflow preventer is
put up before it diverges.
Distance at center: 15.8 - 31.8 in. (401 - 808mm)
Distance on sides
2 - 18 in. (50 - 457mm)
The Quick Connect Cord is 6 ft.(2m) long. Install the units 2-18" (50 - 457mm) apart from each
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).