NCC300 Owner's Guide

37
Water Intlet
Water Outlet
Drain
Hot Water
Service Valve
Pressure Relief Valve
Cold Water
Service Valve
(Ex. NCC300DV (GQ-C5032WZ-FF US))
* Isolation valves may be purchased as an
accessory from an authorized Noritz wholesaler.
They allow for full diagnostic testing and easy
ushingofthesystem.
* The kit includes two full port isolation valves
and a pressure relief valve for the hot side.
Contact Noritz for more information.
Isolation Valves
Forpeoplewholiveinahardwaterarea,periodicalushingisnecessary.IftheHeatExchangeris
not ushed, the Scale Build-up may cause damage to the Heat Exchanger. In this case, this water
heater will detect the Scale Build-up in the Heat Exchanger and then the error code "
"* will be
displayed on the Remote Controller.
When the error code " "*isashingontheRemoteController,theHeatExchangerneedstobe
ushedtopreventdamagefromScaleBuild-up.PleasecontactNoritzAmericaformoreinformation
aboutushingtheHeatExchanger.(http://support.noritz.com/or866-766-7489)
* = 1, 2, 3, 4, F
# = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Total Hardness**
:
200 mg/L (12 gpg) or less
Aluminum : 0.05 to 0.2 mg/L or less
Chloride : 250 mg/L or less
Copper : 1 mg/L or less
Iron : 0.3 mg/L or less
Manganese : 0.05 mg/L or less
pH : 6.5 - 8.5
Total Dissolved Solids : 500 mg/L or less
Zinc : 5 mg/L or less
Sulfate ion : 250 mg/L or less
Residual chlorine : 4 mg/L or less
** Maximum limit suggested by Noritz.
Damage to the water heater as a result of below is not covered by the Noritz America Limited Warranty.
To ensure full warranty coverage, treat or condition water that exceeds the target levels provided in this table.
- Hard water
- Poor water quality (See the below list.)
- The water heater has displayed a " " error code indicating Scale Build-up, but the heat exchanger
hasnotbeenushed.
Source:
EPA National Secondary Drinking Water Regulations (40 CFR Part 143.3)
Water Quality and Maintenance