Specification Sheet
- gas consumption ranges from 15,000 BTUh to
157,000 BTUh
- flow rates from 0.5 gpm up to 7.1 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can be
wall-mounted indoors or outdoors
- available as an Outdoor (requires no venting) or indoor
Direct Vent (-DV) model which includes special plastic flue adapters that are
compatible with both 3” Schedule 40 and 80 PVC/CPVC pipe.
The DV model can also be converted to a non-direct vent (SV) model with
the use of a Conversion Kit (#SV-CK-3)
- 0.94 (NG) 0.94 (LP)
- fully condensing, 93% efficient for use with natural
gas or propane
- includes built in display that can preset the output
temperature to either 120°F, 130°F, 135°F, or 140°F
- 6’ power cord is included with -DV models only
- Flame Rod, Thermal Fuse, Lightning Protection Device (ZNR),
Temperature Lockout, High Elevation Adjustment
- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm]
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a
controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited
Warranty for complete coverage details
** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
CERTIFIED
R
Model NRC711 Series
Residential Condensing Tankless Water Heater
Specification Sheet
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
LOW-LEAD
DV Model
OD Model
NRC711 - ____
Isolation Valves (#IK-WV-200-1(-LF))
Condensate Neutralizer (#NC-1)
3” PVC Termination (#VK3-H-PVC)
Birdscreen for 3” PVC/CPVC (#VT3-PVCS)
Horizontal Hood Termination (#PVT-HL)
DV (Direct Vent)
OD (Outdoor Vent)
SV Conversion Kit (#SV-CK-3)
Outdoor Recess Box (#RB-510)
Remote Controller (#RC-7651M)
Remote Controller Cord (#RC-CORD10)
Pipe Cover (#PC-1S)
Remote Controller Cord (#RC-CORD26)
Overheat Prevention Device, Freezing Prevention Device, Fan Rotation Detector