NRC711-OD-LP Spec Sheet

- gas consumption ranges from 15,000 BTUh to
157,000 BTUh
- flow rates from 0.5 gpm up to 7.1 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can be
wall-mounted indoors or outdoors
- available as an Outdoor (requires no venting) or indoor
Direct Vent (-DV) model which includes special plastic flue adapters that are
compatible with both 3” Schedule 40 and 80 PVC/CPVC pipe.
The DV model can also be converted to a non-direct vent (SV) model with
the use of a Conversion Kit (#SV-CK-3)
- 0.94 (NG) 0.94 (LP)
- fully condensing, 93% efficient for use with natural
gas or propane
- includes built in display that can preset the output
temperature to either 120°F, 130°F, 135°F, or 140°F
- 6’ power cord is included with -DV models only
- Flame Rod, Thermal Fuse, Lightning Protection Device (ZNR),
Temperature Lockout, High Elevation Adjustment
- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm]
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a
controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited
Warranty for complete coverage details
** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
Model NRC711 Series
Residential Condensing Tankless Water Heater
Specification Sheet
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
DV Model
OD Model
NRC711 - ____
Isolation Valves (#IK-WV-200-1(-LF))
Condensate Neutralizer (#NC-1)
3” PVC Termination (#VK3-H-PVC)
Birdscreen for 3” PVC/CPVC (#VT3-PVCS)
Horizontal Hood Termination (#PVT-HL)
DV (Direct Vent)
OD (Outdoor Vent)
SV Conversion Kit (#SV-CK-3)
Outdoor Recess Box (#RB-510)
Remote Controller (#RC-7651M)
Remote Controller Cord (#RC-CORD10)
Pipe Cover (#PC-1S)
Remote Controller Cord (#RC-CORD26)
Overheat Prevention Device, Freezing Prevention Device, Fan Rotation Detector
CERTIFIED
R
LOW-LEAD

Summary of content (2 pages)